• iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
  • iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
  • iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
  • iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
  • iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
  • iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports

Warranty: Min. 2 Years
Display: LCD
Installation: CT Connected
Usage: Power Quality Monitor
Electric Equipment: Three-phase Four-wire
Theory: Electronic Meter
Samples:
US$ 3600/Piece 1 Piece(Min.Order)
| Request Sample
Customization:

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company

Basic Info.

Model NO.
CET iMeter 8
Power Meter Connection
Terminal
Type
PQ Meter
Certification
CE
Customized
Non-Customized
Allow Customized Logo
Yes (MOQ > 1000)
Power Supply
95-250VAC/VDC ± 10%, (Optional 20-60VDC)
Input Voltage
400VLN/690VLL
Rated Current
5A/1A
Measuring Energy
0~99999999999.999kWh
Accuracy
IEC 62053-22 Class 0.2S, SCCPA:IEC62053-21 Class1
Frequency
50/60Hz
Communication
Dual Ethernet Ports, Two RS-485 Ports
Transport Package
Paper Carton
Specification
192(W)x192(H)x182.4(D)
Trademark
CET
Origin
Guangdong, China
HS Code
9028301400
Production Capacity
214000 Pieces/Year

Product Description

CET iMeter 8 3-Phase Class 0.2S LCD Dual Ethernet Ports Two RS-485 Ports Rogowski Coil CT Optional Advanced Power Quality Monitor
iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
The iMeter 8 is CET's Advanced PQ Analyzer designed for the compliance monitoring market as it offers un-surpassed functionality by combining Class 0.2S accuracy and advanced PQ features in a 192x192x182.4mm housing with a High-Resolution, Color Dot-Matrix LCD display. The iMeter 8 complies with such standards as IEC62053-22 Class 0.2S, IEC61000-4-30 Ed. 3.1 Class A, IEC61000-4-15, IEC61000-4-7, EN50160,  IEEE Std 519-2022 as well as IEC61850 for Substation Automation. Further, it offers a large logging capacity with 8GB of on-board memory, extensive I/O, multiple Time Sync. methods, 2x100BaseT Ethernet and 2xRS-485 ports. In addition, it optionally provides 2xAO and 2xAI for different applications. These features likely make the iMeter 8 one of the most advanced PQ Analyzer for an intelligent Power Quality Monitoring System.
 

 Typical Application

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports

• PQ Monitoring at HV, MV and LV Utility Substations
• Data Centers, Semiconductor Fabs, Heavy Industries
• 7x24 Automated Manufacturing Facilities
• Dips, Swells, Interruptions, Transients, Flickers & Harmonics Monitoring

• Mains and Critical Feeder Monitoring
• IEC61850 support for Substation Automation and Smart Grid
• Retrofit Applications with Split-Core Current Probe (SCCP)
 
 Feature Summary

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
 
 Ordering Information

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
 
 Dimensions

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
 
 Technical Specifications

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
 
 Company Profile
iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 PortsiMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
CET has approximately 300 R&D Engineers and a 8000 m2 R&D Center that is strategically located around some of China's Tier 1 Universities in Wuhan.

CET's Production facility is located in Shenzhen's Yantian District, approximately 30 minutes by car from the headquarters, employing about 200 Production workers. CET is fully certified for RoHS manufacturing with an annual production capacity of 600,000 units.

iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports
 
iMeter 8 DIN192 Class 0.2S Three-Phase Advanced Power Quality Analyzer with 8G On-board Memory Extensive I/O Dual Ethernet Two RS-485 Ports


 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

360° Virtual Tour

Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory, Trading Company
Registered Capital
60000000 RMB
Plant Area
>2000 square meters